BCTKX - ZIP GRIP ACCELERATOR

  • MSDS: BCTKX
  • Manufacturer: DEVCON
  • Product Name: ZIP GRIP ACCELERATOR
  • National Stock Number: 6810-00N009856
Product Identification

Product ID:ZIP GRIP ACCELERATOR
MSDS Date:01/01/1987
FSC:6810
NIIN:00N009856
MSDS Number: BCTKX

Responsible Party
DEVCON
30 ENDICOTT STREET
DANVERS, MA 01923

Emergency Phone: 617-777-1100

Info Phone: 617-777-1100

Cage: 16059

Contractor
DEVCON CORP
DANVERS, MA 01923-3753 US

Telephone: 1-508-777-1100

Cage: 16059

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: >98%

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


N OXYDIETHYLENEBENZOTHIAZOLE-2-SULFENIMIDE (OBTS) (AMAX)

CAS: 102-77-2

RTECS: DL5950000

Fraction By Weight: <2%

OSHA PEL NOT KNOWN

ACGIH TLV: NOT KNOWN

Hazards

LD50 LC50 Mixture:ORAL LD50(RAT):8200MG/KG(AMAX) (SUP DAT)
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATL HAVE PRDUCD
SENSTIZATN OF MYOCARDM TO EPINPHRN IN LAB ANIM(DOG),& COULD HAVE
SIMLAR EFFECT IN HMNS,RSULTNG IN FATAL CARDIAC ARRHYTHMIA.DO NOT
USE EPINPHRN/ITS CONGENERS IN PERSONS EX POSD TO THESE CMPDS.
ACUTE:EYES-MILD IRRI,SKN-MAY IRRI ON LNG EXPO,INHAL-DRYNG ON
RESPRTRY(SGN&SYM OVEXPSR)
Explanation of Carcinogenicity:NOT APPLICABLE
Effects of Overexposure:PASSAGES. CFRONIC:OBTS HAS SHIOWN POS EFFECT IN
MUTAGENIC SCREENING. EFFECTS OF OVEREXPOSURE:INHALATION PRODUCES AN
ANESTHETIC EFFECTS. ANESTHETIC EFFECT MAT OCCUR IN THE RANGE OF
1000PPM.
Medical Cond Aggravated by Exposure:ACUTE AND CHRONIC LIVER DISEASE &
RYTHYM DISORDERS OF THE HEART.

First Aid

First Aid:EYE:IMME FLUSH W/LGE AMTS OF WTR FOR AT LEAST 15MIN.IF IRRI
PERSISTS,GET ATTN.SKN:RMOVE CONTAM CLTHNG.WASH W/SOAP & WTR.IF IRRI
PERSISTS,MED ATTN. INGES. INHALATION:REMOVE FROM EXPOSURE. SUPPORT
BREAT HING (GIVE O*2/ARTIFICAL RESPIRATION). GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:>300F/148.9C
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL
Fire Fighting Procedures:WEAR PRESSURE DEMAND SELF-CONTAINED BREATHING
APPARATUS & FULL PROTECTIVE EQUIPMENT
Unusual Fire/Explosion Hazard:THERMAL DECOMP0SITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE

Accidental Release

Spill Release Procedures:VENTILATE AREA.ABSORB IN VERMICULITE/OTHER
SUITABLE ABSORBERNT. SCOOP UP INTO SUITABLE DISPOSAL CONTAINERS.
WEAR PROCTIVE CLOTHING6 RESPIRATORY PROTECTION, IF NEEDED.
Neutralizing Agent:NOT KNOWN

Handling

Handling and Storage Precautions:FOR INDUSTRL USE W/ADEQUA TE
VENTILATION.
Other Precautions:READ INSTRUCT SHEET CARFLLY.DO NOT WEAR CNTCT
LENS.AVOID CNTCT W/SKN,EYE/CLTHNG.DO NOT ADD DIREC TO ANY
CYANOCRYLATE ADHE. A VIOLNT EXOTHRMC REACTN WLL OCCUR.NO SMK IN
AREA OF USE.DO NOT USE IN GEN VI CIN OF ARC WELDNG,OPEN FLAME
OR(SUP DAT)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN
Ventilation:MECHANICALLY EXHAUST TO OUTSIDE TO KEEP WORK AREA BELOW
TLV.
Protective Gloves:IMPERVIOUS TYPE,NOT CLOTH/NATURAL RUBBR
Eye Protection:SAFETY GLASSES,GOGGLES/FACE SHIELD
Other Protective Equipment:NOT KNOWN
Work Hygienic Practices:AVOID CONTACT W/SKIN, EYES/CLOTHING.
Supplemental Safety and Health
FL PT MTD:N.LD50-LC50 MIX:DERM LD50(RAB)-7940MG/KG(AMAX).OTHR PRECA:HOT
SURFACE.HEAT &/UV RAD MAY CAUS FORM OF HCL &/PHOSGENE. TLV OF
PRODUCT:350 PPM(MFR).RTE OF ENTRY:FPN

Chemical Properties

Boiling Pt:B.P. Text:165F/73.9C
Decomp Temp:Decomp Text:N/K
Vapor Pres:100
Vapor Density:4.55
Spec Gravity:1.33
pH:9.5
Evaporation Rate & Reference:12.8
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID,ETHER LIKE ODOR
Percent Volatiles by Volume:>60
Corrosion Rate:N/K-FP

Stability

Stability Indicator/Materials to Avoid:YES
CORRO TO ALU.MIX W/CYANOCRYLATE ADHESIVES WULL CAUS VIOLNT REACTS
W/NITRITES, 0*2, NA NAOH.
Stability Condition to Avoid:HIGH TEMPERATURE,HOT METALS,UV RADIATION
Hazardous Decomposition Products:AT VERY HIGH TEMP,AS IN OPEN FLAMES,
CAN FORM HCL, PHOSGENE, & OTHER TOXIC FUMES.
Conditions to Avoid Polymerization:HIGH TEMPERATURES, HOT METALS, UV
RADIATION.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCOSRDANCE W/ ALL FEDERAL,STATE,&
LOCAL REGULATIONS CONCERNING HEALTH & ENVIRONMENT. DO NOT POUR DOWN
DRAIN

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.